Product Overview

The Dynasonics TFX-500w is Badger Meter’s cost-effective clamp-on transit-time ultrasonic flow meter built specifically for clean water — two transducers strap to the outside of the pipe and time a frequency-modulated burst sent with and against the flow, so it measures bidirectional flow with no wetted parts, no pressure drop and no moving parts on a live line. It covers pipes from 1/2 to 10 in. (15–250 mm / DN250) at ±1% of reading with ±0.2% repeatability, reads flow, total and velocity on a backlit graphical display, and communicates over Modbus RTU or BACnet MS/TP with AquaCUE / endpoint connectivity for automatic meter reading. Integral or remote-mount, 24 V DC powered, with SoloCUE software for setup, it is the focused, economical Dynasonics choice when the fluid is water and the line must stay in service.

Other Dynasonics options for different needs
TFX-5000 — wider pipe range, energy/BTU, hazardous-area builds DXN-5P portable — hybrid transit-time / Doppler portable kit E-Series G2 — inline lead-free bronze meter, NSF 61
Dynasonics TFX-500w clamp-on transit-time ultrasonic water flow meter (Badger Meter)
Dynasonics TFX-500w — cost-effective clamp-on transit-time ultrasonic water flow meter; 1/2–10 in., non-invasive.

Key Features & Benefits

  • Reads a live line — the transducers strap on outside the pipe, so the meter goes in without cutting, tapping, draining or air-purging — the system keeps running through the install
  • Water-focused and value-priced — a clamp-on built specifically for clean-water duty to 10 in., it carries the non-invasive benefits without the wider-range and energy options you would not use on a water line
  • One meter into the BMS and the AMR system — Modbus RTU / BACnet MS/TP over RS-485 drops it onto a building-automation or SCADA bus, and AquaCUE / endpoint connectivity carries the reading to automatic meter reading
  • Reads at the meter or from software — a large backlit graphical display and keypad show flow, total and velocity locally, while SoloCUE handles configuration and troubleshooting from a laptop
  • Submersible transducer option — the WZ set is rated IP68, so the clamp-on point can sit in a flooded vault or pit that a standard set could not

Specifications

Measurement principle
Clamp-on transit-time ultrasonic — a pair of strap-on transducers alternately send a frequency-modulated ultrasonic burst downstream and upstream; the difference in time-of-flight is proportional to fluid velocity. The transducers never contact the water.
Accuracy
±1% of reading (or ±0.01 ft/s / 0.003 m/s, whichever is greater) on pipes over 2 in.; ±1% of reading ±0.03 ft/s (0.01 m/s) on 1–2 in. (25–50 mm); 3/4 in. (20 mm) and smaller are ±1% of full scale
Repeatability
±0.2% of reading
Turndown / flow range
Bidirectional, with a velocity range up to 0.1–40 ft/s (0.03–12 m/s) depending on pipe and fluid
Pipe sizes
1/2–10 in. (15–250 mm / DN250) — the focused water-pipe range
Pipe materials
PVC, CPVC, HDPE, PTFE, PVDF, stainless steel, ductile iron, aluminium, brass, carbon steel and copper; lined, heavily-scaled or fibreglass walls are reviewed case by case
Transducers
Clamp-on transducers sized to the pipe — fixed small-pipe (CA–CT) and adjustable small-rail (UZ) for 1/2–2 in., standard (RZ / NZ) sets for 2.5–10 in. (DN65–DN250), and Easy-Rail sets — JZ for 2.5–6 in. (DN65–DN150), KZ for 2.5–10 in. (DN65–DN250) — plus a submersible (WZ, IP68) option; cable to 300 ft (90 m) remote
Compatible fluids
Clean water containing only small amounts of suspended solids or gas bubbles — potable, reclaimed, chiller, boiler-feed and make-up water
Fluid temperature
Set by the transducer: the NZ / WZ standard-pipe and small-pipe (CA–CT / UZ) sets to about 194°F (90°C); the RZ standard-pipe and JZ / KZ Easy-Rail sets to 250°F (121°C)
Mounting / installation
Transducers clamp to the outside of the pipe; the transmitter is integral, or wall / pipe remote-mount and rotatable in 90° increments — installed without shutting the line down. Allow 10 pipe diameters upstream and 5 downstream from a single elbow
Outputs
Bidirectional flow rate, total and velocity in field-selectable engineering units; two configurable pulse / frequency / digital outputs, an isolated 0/4–20 mA analog output, and a digital input for totalizer reset / alarm unlatch
Communication options
Modbus RTU or BACnet MS/TP (BTL-certified) over RS-485, with AquaCUE® / endpoint connectivity for automatic meter reading
Enclosure / rating
IP66 polycarbonate transmitter enclosure (integral or remote); the WZ transducer set is submersible to IP68
Display
Backlit 128×64 graphical display with a 4-button membrane keypad, or a no-display keypad build; full setup and diagnostics via the SoloCUE Flow Device Manager software over USB
Power
24 V DC (9–28 V DC at 5 W maximum, Class II supply)
Approvals & standards
Factory wet-calibrated as standard; an Optional stainless-steel ID / calibration tag, and an Optional general-area US / Canada safety listing (FM / CSA to 61010-1) are orderable; CE (EMC Directive)

Common Applications

  • Commercial-building and campus water-distribution metering, new or retrofit
  • Potable and reclaimed-water lines
  • Chiller-water and boiler feed-water measurement
  • Make-up water to cooling towers and heating loops
  • Water submetering tied to AquaCUE for facility water-use tracking
  • Retrofit water metering where the line cannot be shut down or cut into
The TFX-500w is built for water; if the line carries oil, glycol heat-transfer fluid or a wider pipe range — or you need energy / BTU or a hazardous-area build — the TFX-5000 is the broader-duty clamp-on. Use the input form to tell us the fluid and pipe and we’ll confirm the fit.

Design & Selection Considerations

  • Match the method to the fluid — transit-time vs Doppler — transit-time meters time an ultrasonic pulse sent with and against the flow, so they want a clean to lightly-laden liquid that passes sound (the TFX-5000 clamp-on and E-Series G2 inline). A Doppler meter (the DFX) does the opposite — it needs suspended solids or aeration to reflect the signal, which is what makes it the pick for sewage, slurries and aerated fluids. Use the input form to tell us how clean the fluid is and the right principle follows; the wrong one simply will not read.
  • Clamp-on or inline — non-invasive vs best low-flow accuracy — a clamp-on meter straps transducers to the outside of the pipe — no cut-in, no pressure drop, no wetted parts, and it installs on a live line (the TFX-5000 / TFX-500w, and the portable DXN-5P). An inline spool (E-Series G2) is a permanent wetted body that holds the tightest low-flow accuracy and carries potable-water approval. Retrofit and survey work favour clamp-on; a permanent metered point with tight accuracy favours inline.
  • Clamp-on needs a sound-friendly pipe — a clamp-on meter sends sound through the wall, so it wants a solid, sonically-conductive pipe of known material and wall thickness — metal and most plastics read well; heavy mortar lining, fibreglass, gas pockets, or badly corroded / scaled wall scatter the signal. Use the input form to give us the pipe material, OD and wall and we confirm suitability and transducer choice. The pipe is part of the meter on a clamp-on install — spec it as carefully as the fluid.
  • Give the meter a developed flow profile — ultrasonic meters tolerate less straight run than a turbine, but a swirling or distorted profile off elbows, pumps and valves still biases the reading. Allow the recommended upstream / downstream straight run, or mount on the longest available run. More straight run, steadier reading — design the location, do not just clamp where it is convenient.
  • Specify potable / hygienic approval where it is required — for drinking-water service the body must be lead-free and certified — the inline E-Series G2 carries a lead-free bronze body to NSF/ANSI 61 & 372. Say up front that the line is potable and we specify an approved body, not a general-purpose one. Approval is a build choice, not a field add-on.
  • For heating / cooling energy, pair flow with a matched RTD pair — thermal energy is flow × the supply-return temperature difference, so an energy meter needs a matched temperature-sensor pair as well as flow. The UHC-120 integrates ultrasonic flow with the RTD pair to EN 1434, and the FC-215 computes energy from an external flow signal and RTD pair. For BTU / tenant billing, the matched sensor pair and the standard matter as much as the flow reading.
  • Open channel: non-contact level or submerged area-velocity — in an open channel, flow is derived from level over a known primary device, or from velocity × area. The IS-4000 reads level non-contact over a flume or weir — nothing in the stream to foul; the IS-6000 submerges an area-velocity Doppler sensor where there is no primary device or the channel surcharges. A flume / weir site suits non-contact level; a surcharging or primary-less channel suits area-velocity.

To size & select the right Dynasonics TFX-500w:

Use the input form to send your pipe size and material (or line size), the fluid and how clean it is, the flow range and accuracy target, and the fluid temperature — with whether you need clamp-on or inline, energy / BTU, or open-channel — and we’ll spec the right Dynasonics meter, transducers and outputs for your application.

Flow Meter Application Sheet ›

Talk to an engineer directly — Scott Prater, Principal · 917-580-0878 · scott@pratertechnical.com

Specifications compiled by Prater Technical Partners from Badger Meter Dynasonics ultrasonic flow product literature.